Purpose
The all-inclusive TMS check stand is a complete testing complex for incoming inspection, post-repair verification, and metrological calibration of submersible and surface telemetry system blocks from various manufacturers.
System Components
Thermal Test Cabinet
An 8-section electric furnace for simultaneous testing of up to 8 submersible blocks. Each section has independent heating (4 kW each, 32 kW total) with individual temperature control. Combined convection and radiation heating ensures rapid warm-up without overshoot.
Vibration Table
Verifies vibration measurement channels and overall system stability under vibration. Lightweight table design enables high vibration amplitude at lower vibrator power.
Hydraulic Test Table
Verifies pressure sensor readings using the compression method in manual and automatic modes. Includes high-pressure pump, manifold, and reference pressure gauge.
Control Rack
Industrial PC (Mini-ITX), switching equipment, monitor, keyboard, I/O modules. Runs Cross-Start software for full test automation and protocol generation.
Technical Specifications
| Parameter | Value |
|---|---|
| Hydraulic system fluid | Oil VMGZ-45 |
| Maximum working pressure | 60 MPa |
| Maximum test temperature | 150°C |
| Test time per block | 30–120 min |
| Maximum block dimensions (L×D) | 1100×130 mm |
| Maximum block weight | 50 kg |
| Simultaneous thermal testing | Up to 8 blocks |
| Vibration table capacity | 1 block |
| Power supply | 380 V, 50 Hz |
| Total power consumption | 34 kW |
| Noise level | 90 dB |
* Custom manufacturing according to your technical specifications is available, considering the specified parameters and specific requirements.