Purpose
Specialized testing complex for leak testing of heating cable termination devices by the hydrostatic pressure method up to 10 MPa. Dual control is implemented: by pressure and by electrical resistance of conductors.
Design
Monoblock mobile design — all components integrated into a single enclosure on casters. The fully automatic test cycle is managed by Cross-Start software with protocol generation.
Key Features
- Dual leak detection: pressure + electrical resistance
- Monoblock mobile design
- Fully automatic test cycle
- 5,000-hour MTBF, 10-year service life
Technical Specifications
| Parameter | Value |
|---|---|
| Product diameter | Up to 50 mm |
| Termination length | Up to 400 mm |
| Product weight | Up to 2 kg |
| Working fluid | Water / water with reagent |
| Pressure range | 0–10 MPa (0–100 atm) |
| Operating modes | Automatic, semi-automatic |
| Setpoint accuracy | ≤2% |
| Measurement accuracy | ≤0.25% |
| Power supply | 3×380 V, 50 Hz |
| Power consumption | ~10 kW |
| Dimensions (W×D×H) | 1800×700×1200 mm |
| Weight | ~800 kg |
| MTBF | 5,000 hours |
| Service life | 10 years |
Request a Quote
* Custom manufacturing according to your technical specifications is available, considering the specified parameters and specific requirements.